Radon Mitigation Testing at Its Best

Lifetime Radon Mitigation is providing best services to its clients. As our process firstly involves the visual survey of the place after that the whole system is installed. In the mitigation visual survey, it is determined and find out that how much quantity of radon is present, with which process it can be easily removed and how much powerful fan is required for the gas to be effectively removed. After complete inspection, the system is installed. System consists of pipes, elbows and fan mainly. The hole is dig in the basement of the house with the mechanical force. After it inside assembly is installed then fan is next in the line and finally the outer duct if assembled.

After the complete installation of the radon mitigation system it is necessary to inspect the system occasionally. In order to perform testing the key instrument required is the pressure gauge. This gauge shows us the amount of the gas induced by the fan. A test is completely lined with the previous test. As the difference between the two tests can show us that how effectively our radon mitigation system is working. So, we are providing radon testing Madison WI solutions to our clients. The pipe assembly is connected with the basement so that to provide a proper channel for the flow of the radon gas. The channel is the key for the proper working of radon mitigation system. For testing the digital manometer is connected with the inlet and outlet of the fan so the manometer shows us the reading that either our system is working properly or not. The manometer is firstly calibrated to make sure that it shows zero reading. During testing the fan working capacity is increased to its maximum value. At maximum value the fan speed and manometer readings are noted down. The reading from the basement is also noted down. And the reading of the digital manometer applied around the fan should be higher than the reading at the basement entrance pipe. In testing we also go for any kind of leaks in the pipe assembly and also over view the other problems. Then a complete assessment report is made and compared with the previous one and from the reading it is concluded that either the radon mitigation assembly is working properly or not. The testing also involves the cleaning of the draining duct so that if there are any debris inside pipe they are removed. Testing is not expensive but will cost you maximum of $120. But for the longer life span of the radon mitigation system we suggest you to hire our experts for occasionally testing. Our way of working, material of constructions we used are long lasting and we guarantee this. Lifetime Radon Mitigation is devoted towards its customers and we provide the best available in the market. We are working according to the rules and regulations of Environmental Protection Agency (EPA) and other regulations authorities in the country.

 

About The Author